lt en ru
Autotestas header

They are used to control the electrical operation of compressors, pumps, presses, hydraulic and pneumatics equipment. The contacts open or close the circuit depending on the position of the indicating pointer and they are adjustable over the whole range. For application on severe working conditions, such as rapid and frequent pressure change, vibration and pulsation, they are manufactured with the case liquid filled. The filling drastically reduces the effect of such factors as well as those caused by a corrosive atmosphere, giving longer life and better performances of the pressure gauge and their electric contacts. They are also available with inductive contacts intrinsecally safe.

Technical specifications

Type

MGS72

MGS74

Case diameter

DN 100

DN 100

Parts inside

copper alloy

AISI316L

Range

0/1,6 – 0/600 bar
vacuum
pressure and vacuum

0/1 – 0/600 bar
vacuum
pressure and vacuum

Contact

SPDT microswitch

SPDT microswitch

Accuracy class

2,5

2,5

Protection degree

IP 44

IP 44

Datasheet

EN

EN

 

Type

MN14/10

MN14/18

Case diameter

DN 100-150

DN 100-150

Parts inside

copper alloy

AISI316L

Range

0/1,6 – 0/1000 bar

0/1 – 0/1600 bar
vacuum
pressure and vacuum

Contacts

mounted on top: mechanical, magnetic or inductive

mounted on top: mechanical, magnetic or inductive

Accuracy class

1,0

1,0

Protection degree

IP 44...IP 55

IP 44...IP 55

Datasheet

EN

EN

 

Type

MCE10

MCE18

MCE20

Case diameter

DN 100

DN 100

DN150

Parts inside

copper alloy

AISI316L

AISI316L

Range

0/1 – 0/1000 bar

0/1 – 0/1600 bar
vacuum
pressure and vacuum

0/1 – 0/1600 bar
vacuum
pressure and vacuum

Contacts

mechanical, magnetic, inductive or electronic

mechanical, magnetic, inductive or electronic

mechanical, magnetic, inductive or electronic

Accuracy class

1,0

1,6...1,0

1,6...1,0

Protection degree

IP 55...IP 67

IP 55...IP 67

IP 55...IP 67

Features

 

 

„Solid-Front“

Datasheet

EN RU

EN

EN RU

 

Type

MCE10/SF6

MCE18/SF6

Case diameter

DN 100

DN 100

Parts inside

copper alloy

AISI316L

Range

-1/0,6 – -1/24 bar

-1/0,6 – -1/24 bar

Contacts

mechanical, magnetic or inductive

mechanical, magnetic or inductive

Accuracy class

1,0

1,0

Protection degree

IP 44...IP 55

IP 44...IP 55

Features for SF6 gas monitoring for SF6 gas monitoring

Datasheet

EN

EN

Information about electric contacts.
Information about electronic-inductive contacts.

Manufacturer:
NUOVA FIMA (Italy).